福祿克Fluke 190-504彩色數(shù)據(jù)示波表
福祿克Fluke 120B 系列 ScopeMeter?工業(yè)用手持式示波表
福祿克Fluke-190-204/S ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-502 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-202 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-102 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-104 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-062 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke OptiFiber? Pro?OTDR系列
福祿克Fluke CertiFiber?光纖損耗測(cè)試套件
福祿克Fluke SimpliFiber? Pro光功率計(jì)和光纖測(cè)試儀
福祿克Fluke Fiber QuickMap?多模光纖距離和故障定位儀
福祿克Fluke Fiber OneShot? PRO光纖測(cè)試儀
福祿克Fluke VisiFault? Visual Fault Locator電纜連通性測(cè)試儀
福祿克Fluke MultiFiber? Pro光功率計(jì)及光纖測(cè)試工具包
福祿克Fluke FI-7000 FiberInspector? Pro光纖顯微攝像機(jī)
EXFO FTBx-720CLAN/WAN接入網(wǎng)OTDR光時(shí)域反射儀
EXFO FTBx-730CPON FTTx/MDU OTDR光時(shí)域反射
EXFO FTBx-735C城域網(wǎng)/PON FTTx/MDU OTDR光時(shí)域反射儀
EXFO FTBx-750C城域網(wǎng)/長(zhǎng)距離OTDR光時(shí)域反射儀
EXFO MaxTester 710BOTDR光時(shí)域反射儀
EXFO MaxTester 715BOTDR光時(shí)域反射儀
EXFO MaxTester 720C接入網(wǎng)OTDR光時(shí)域反射儀
EXFO MaxTester 710B最后一英里OTDR
NetAlly LinkRunner? G2智能有線網(wǎng)絡(luò)測(cè)試儀
NetAlly LinkRunner? AT網(wǎng)絡(luò)自動(dòng)測(cè)試儀
NetAlly OneTouch? AT G2網(wǎng)絡(luò)性能測(cè)試儀
NetAlly EtherScope nXG便攜式網(wǎng)絡(luò)專業(yè)智能測(cè)試工具
NetAlly LinkRunner 10G高級(jí)以太網(wǎng)測(cè)試儀
福祿克Fluke LinkIQ?線纜+網(wǎng)絡(luò)測(cè)試儀
NetAlly LinkSprinter?口袋便攜式網(wǎng)絡(luò)測(cè)試儀
福祿克Fluke EtherScope II網(wǎng)絡(luò)通二代
福祿克Fluke OptiFiber? Pro?OTDR系列
橫河YOKOGAWA AQ1000掌上型光時(shí)域反射儀
橫河YOKOGAWA AQ1210系列光時(shí)域反射儀
EXFO FTBx-720CLAN/WAN接入網(wǎng)OTDR光時(shí)域反射儀
EXFO FTBx-730CPON FTTx/MDU OTDR光時(shí)域反射
EXFO FTBx-735C城域網(wǎng)/PON FTTx/MDU OTDR光時(shí)域反射儀
EXFO FTBx-750C城域網(wǎng)/長(zhǎng)距離OTDR光時(shí)域反射儀
EXFO MaxTester 710BOTDR光時(shí)域反射儀
福祿克Fluke 1621接地電阻測(cè)試儀
梅凱(梅格)Megger DET14C/DET24C接地電阻鉗形數(shù)字測(cè)試儀
梅凱(梅格)Megger DET3TC/DET3TD三極接地電阻測(cè)試儀
梅凱(梅格)Megger DET2/3高分辨率接地測(cè)試儀
梅凱(梅格)Megger DET4T2系列接地電阻測(cè)試儀和土壤電阻測(cè)試儀
福祿克Fluke 1623-2/1623-2KIT接地電阻測(cè)試儀
福祿克Fluke 1625-2/1625-2KIT接地電阻測(cè)試儀
福祿克Fluke 1630-2FC接地環(huán)路電阻測(cè)試鉗表
福祿克Fluke 190-504彩色數(shù)據(jù)示波表
泰克Tektronix MDO3000混合域示波器
福祿克Fluke 120B 系列 ScopeMeter?工業(yè)用手持式示波表
福祿克Fluke-190-204/S ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-502 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-202 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-102 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-104 ScopeMeter?彩色數(shù)字示波表
洞察行業(yè)資訊 分享專業(yè)知識(shí)
洞察行業(yè)資訊 分享專業(yè)知識(shí)
全國(guó)統(tǒng)一服務(wù)熱線:
134 1039 1245
400-996-0787
0755-8399 9818
聯(lián)系郵箱:
sales@faxytech.com
聯(lián)系地址:
深圳市福田區(qū)華強(qiáng)北路華聯(lián)發(fā)大廈602室
A YouTube video explaining how this this works is also?available from here.
This is applicable to the following cabling standards only:
ISO/IEC 11801
EN 50173
Aus/NZ
JIS
When?the Insertion Loss is less than 4.0 dB at the frequency point where the measurement is made, then the measurement is ignored and not uated against the selected Test Limit/Cabling Standard in the DTX CableAnalyzer. This is often referred to as the 4 dB rule. It is not applied in the North American TIA Cabling Standards. Only certain test parameters and configurations will have the 4 dB rule. The tables below indicate which link? definitions and test parameters have the 4 dB rule applied to them. As an aid, the other rules are also listed.
On a?short link, the Insertion Loss may never reach 4.0 dB. If that were to happen, then the entire measurement would be?ignored, or as the cabling standards phrase it; “recorded for information only”. If this were to happen with your DTX CableAnalyzer, you would see an “i” appear next to the summary result for that test parameter. In LinkWare software, the result would be recorded with “N/A’. An example is shown below:
Concern is normally caused when the result has a negative margin. In this example we see the NEXT margin was -9.7 dB. A?negative margin is normally associated with a FAIL, but because the entire link never exceeded 4.0 dB Insertion Loss, it’s not a FAIL. Further?confusion lies in that the North American ANSI/TIA/-568-C.0 cabling standard does not have this 4 dB rule. If you were to test the same link above?with the same DTX CableAnalyzer, but using the North American Standard TIA Cat 5e Perm. Link, your result would be a FAIL.
Please make sure you?have agreed in a Test Limit, in writing, before the project starts.
Let’s review in detail how this works by looking at another example test result on the DTX CableAnalyzer.
An ISO11801 PL Max Class D AUTOTEST was run on a short 6.0 m installed link, giving the following result:
Looks normal. Let’s take a look at the NEXT result in a little more detail:
You will observe that?the limit line has two colors, black and red. The cabling standards do not require the cable tester manufacturer to display where the 4 dB rule is implemented to the user, only that it is implemented. However, the DTX CableAnalyzer will indicate where the 4 dB rule has been implemented by changing the color of the limit line. If the?limit line is black,?the Insertion Loss was less than 4.0 dB. If?the limit line is red,?the Insertion Loss was 4.0 dB or greater. So for this Pair 1,2-4,5 the NEXT is not uated below 84.8 MHz. Let’s take a quick look at the Insertion Loss for Pair 4,5:
As you can see, the Insertion Loss reached 4.0 dB at 84.8 MHz, as previously indicated in the NEXT Pair 1,2-4,5 graph above. NEXT contains two pairs. So which Insertion Loss pair do we use to implement the 4 dB rule? The disturbed pair is used for uation purposes. So if the worst case NEXT Pair was 1,2-7,8 then the?DTX CableAnalyzer would use the Insertion Loss values from Pair 7,8 to determine where the 4 dB rule is implemented.
As previously mentioned, if the link is particularly short, then the Insertion Loss may never reach 4.0 dB and the entire NEXT result is “ignored”. Let’s take a closer look at the first example where the test result was:
Looking at the worst case NEXT result, we see the entire limit line is black, suggesting that the Insertion Loss for Pair 4,5 never reached 4.0 dB:
Looking at the Insertion Loss for Pair 4,5:
We see that the Insertion did indeed never reach 4.0 dB, so the entire measurement is not uated against the limit line (ignored) and recorded as “i” Information Only. If this result was downloaded to LinkWare Software, the report would show N/A against this measurement:
No further action is required by the installer. This is a valid standards compliant result.
Copyright? 1998-2023深圳市連訊達(dá)電子技術(shù)開發(fā)有限公司 All Rights Reserved .
地址:深圳市福田區(qū)華強(qiáng)北路華聯(lián)發(fā)大廈602室 客服:400-966-0787
備案號(hào):
粵ICP備18089363號(hào)
網(wǎng)站地圖
免責(zé)聲明:福祿克、FLUKE、FLUKE NETWORKS、 NETALLY等品牌資料及圖片摘自網(wǎng)絡(luò),連訊公司不擁有以上品牌商標(biāo)及相關(guān)產(chǎn)品著作權(quán)。