福祿克Fluke 190-504彩色數(shù)據(jù)示波表
福祿克Fluke 120B 系列 ScopeMeter?工業(yè)用手持式示波表
福祿克Fluke-190-204/S ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-502 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-202 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-102 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-104 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-062 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke OptiFiber? Pro?OTDR系列
福祿克Fluke CertiFiber?光纖損耗測試套件
福祿克Fluke SimpliFiber? Pro光功率計(jì)和光纖測試儀
福祿克Fluke Fiber QuickMap?多模光纖距離和故障定位儀
福祿克Fluke Fiber OneShot? PRO光纖測試儀
福祿克Fluke VisiFault? Visual Fault Locator電纜連通性測試儀
福祿克Fluke MultiFiber? Pro光功率計(jì)及光纖測試工具包
福祿克Fluke FI-7000 FiberInspector? Pro光纖顯微攝像機(jī)
EXFO FTBx-720CLAN/WAN接入網(wǎng)OTDR光時(shí)域反射儀
EXFO FTBx-730CPON FTTx/MDU OTDR光時(shí)域反射
EXFO FTBx-735C城域網(wǎng)/PON FTTx/MDU OTDR光時(shí)域反射儀
EXFO FTBx-750C城域網(wǎng)/長距離OTDR光時(shí)域反射儀
EXFO MaxTester 710BOTDR光時(shí)域反射儀
EXFO MaxTester 715BOTDR光時(shí)域反射儀
EXFO MaxTester 720C接入網(wǎng)OTDR光時(shí)域反射儀
EXFO MaxTester 710B最后一英里OTDR
NetAlly LinkRunner? G2智能有線網(wǎng)絡(luò)測試儀
NetAlly LinkRunner? AT網(wǎng)絡(luò)自動測試儀
NetAlly OneTouch? AT G2網(wǎng)絡(luò)性能測試儀
NetAlly EtherScope nXG便攜式網(wǎng)絡(luò)專業(yè)智能測試工具
NetAlly LinkRunner 10G高級以太網(wǎng)測試儀
福祿克Fluke LinkIQ?線纜+網(wǎng)絡(luò)測試儀
NetAlly LinkSprinter?口袋便攜式網(wǎng)絡(luò)測試儀
福祿克Fluke EtherScope II網(wǎng)絡(luò)通二代
福祿克Fluke OptiFiber? Pro?OTDR系列
橫河YOKOGAWA AQ1000掌上型光時(shí)域反射儀
橫河YOKOGAWA AQ1210系列光時(shí)域反射儀
EXFO FTBx-720CLAN/WAN接入網(wǎng)OTDR光時(shí)域反射儀
EXFO FTBx-730CPON FTTx/MDU OTDR光時(shí)域反射
EXFO FTBx-735C城域網(wǎng)/PON FTTx/MDU OTDR光時(shí)域反射儀
EXFO FTBx-750C城域網(wǎng)/長距離OTDR光時(shí)域反射儀
EXFO MaxTester 710BOTDR光時(shí)域反射儀
福祿克Fluke 190-504彩色數(shù)據(jù)示波表
泰克Tektronix MDO3000混合域示波器
福祿克Fluke 120B 系列 ScopeMeter?工業(yè)用手持式示波表
福祿克Fluke-190-204/S ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-502 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-202 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-102 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-104 ScopeMeter?彩色數(shù)字示波表
洞察行業(yè)資訊 分享專業(yè)知識
洞察行業(yè)資訊 分享專業(yè)知識
全國統(tǒng)一服務(wù)熱線:
134 1039 1245
400-996-0787
0755-8399 9818
聯(lián)系郵箱:
sales@faxytech.com
聯(lián)系地址:
深圳市福田區(qū)華強(qiáng)北路華聯(lián)發(fā)大廈602室
福祿克DTX-1800或者DTX-1500的10%長度原則(10% rule for length – DTX CableAnalyzer)
你是否在使用福祿克DTX-1800或者DTX-1500的時(shí)候長度會超出標(biāo)準(zhǔn)極限值?
Example1:
(The display here is from?DTX Version 2.74, have you updated your DTX CableAnalyzer?)
這個(gè)結(jié)果是對的嗎?這長度已經(jīng)超出了90M。
從ANSI/TIA-1152工業(yè)標(biāo)準(zhǔn),我們發(fā)現(xiàn):
4.2.3.1無論速度和電磁速度。
4.2.3.1 Physical length vs.?electrical length
The pass or fail criteria is based on the maximum length allowed for the channel or permanent link as specified in ANSI/TIA-568-C.2 plus the nominal velocity of propagation (NVP) uncertainty of 10 %.
通過和失敗的判斷標(biāo)準(zhǔn)是依據(jù)ANSI/TIA-568-C.2 通道和永久的標(biāo)準(zhǔn)加上NVP速度的10%不確定性。
This means that although the limit is 90.0 m (295 ft), the tester will not fail the length parameter until the shortest pair of the four pairs has exceeded 90 m + 10 % (99 m) or 295 ft + 10% (325 ft). In the example above, the shortest pair was 92.5 meters, less than the 90 m + 10 % permitted by this standard.
這就意味著盡管極限標(biāo)準(zhǔn)是90M,但是DTX-1800或者DTX-1500顯示92.5M,小于90M+10%的允許量。
Many customers do not like/agree with this feature. However, your DTX-1800或者DTX-1500 CableAnalyzer is standards based. Whilst Fluke Networks may not necessarily agree with the 10 % fudge rule, the industry agreed to this. We implement the standard as is. THIS IS NOT AN EXCUSE TO GO BEYOND 90 m!!!!!!!!!!! If the cable is marginally compliant, insertion loss will fail before length fails.
許多客戶也許覺得不同意但是福祿克DTX-1800或者DTX-1500是根據(jù)標(biāo)準(zhǔn)來的。福祿克網(wǎng)絡(luò)的設(shè)備也許沒有必要咨詢10%長度原則,但是工業(yè)標(biāo)準(zhǔn)支持,所以,我們根據(jù)標(biāo)準(zhǔn)制定了。
This rule applies to channel limits as well where the length limit is 100 m (328 ft). However, because of clause?4.2.3.1 in the standard, the length test will not fail until the shortest pair of the four pairs measured exceeds 100 m + 10 % (110 m) or 328 ft + 10% (361 ft).
It is important to understand that we used the shortest pair to report the length of the link. Again, this is detailed in clause 4.2.3.1 of ANSI/TIA-1152.
When physical length is determined from electrical length, the physical length of the link calculated using the pair with the shortest electrical delay shall be reported and used for making the pass or fail decision.
Example 2:
(The display here is from DTX Version 2.74, have you updated your DTX CableAnalyzer?)
Here we see that the shortest pair is 7,8 with a length of 97.9 m and hence a PASS since it does not exceed the 90 m limit by more than 10%. The other two pairs did exceed 90 m plus 10% and are marked I for Information Only but are not used for uating the link.
我們通過上圖可以看到DTX-1500顯示的7.8線對是97.9M,結(jié)果顯示是通道。因?yàn)樗鼪]有超過90M的百分百之十。其他兩對線路已經(jīng)超過了10%并且標(biāo)記了I對于參考,但是我們沒有評價(jià)沒有用作評價(jià)對這條鏈路。
Example 3:
If the pair with the shortest length exceeds 90 m plus 10%, then length is reported as FAIL (shown below).
如果所有的都顯示超過90M+10%,那么它就會顯示失敗了。
Copyright? 1998-2023深圳市連訊達(dá)電子技術(shù)開發(fā)有限公司 All Rights Reserved .
地址:深圳市福田區(qū)華強(qiáng)北路華聯(lián)發(fā)大廈602室 客服:400-966-0787
備案號:
粵ICP備18089363號
網(wǎng)站地圖
免責(zé)聲明:福祿克、FLUKE、FLUKE NETWORKS、 NETALLY等品牌資料及圖片摘自網(wǎng)絡(luò),連訊公司不擁有以上品牌商標(biāo)及相關(guān)產(chǎn)品著作權(quán)。